Pagina 1 - AUTOMATIC TRANSFER SWITCHES

9087A – 198th Street, Langley, BC Canada V1M 3B1  Telephone (604) 888-0110 Telefax (604) 888-3381  E-Mail: [email protected]  www.th

Pagina 2

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 6 Thomson Technology System load is then automatically re-transferred back to the utility supply fol

Pagina 3 - TABLE OF CONTENTS

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 7 Thomson Technology 4.1. PRODUCT MODEL CODE The type of TS 870 series transfer switch supplied is

Pagina 4 - (ALL MODELS WITH INTEGRAL

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 8 Thomson Technology 4.2. TYPICAL COMMISSIONING PROCEDURES CAUTION: Commissioning procedures must

Pagina 5 - 2. EQUIPMENT STORAGE

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 9 Thomson Technology will be initiated. Once the warm-up timer expires (adjustable from 0 to 60 sec

Pagina 6 - 3. NOTES TO INSTALLER

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 10 Thomson Technology the load to the generator supply. The utility source will be locked out and th

Pagina 7

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 11 Thomson Technology switch will immediately return to the utility or generator supply if within no

Pagina 8

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 12 Thomson Technology to remove utility control power. To isolate the generator supply, re

Pagina 9 - 4. GENERAL DESCRIPTION

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 13 Thomson Technology 5. Attach a safety lockout padlock to the service disconnect control switch to

Pagina 10 - TS 870 TRANSFER SWITCH

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 14 Thomson Technology 200A, over current protection is non-adjustable thermal-magnetic type trip uni

Pagina 11 - 4.1. PRODUCT MODEL CODE

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 15 Thomson Technology 7. GENERAL NOTES ON SERVICING TRANSFER SWITCH MECHANISM DANGER!!!! Arc Flash

Pagina 13 - 5.2.2. OVER CURRENT TRIP

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 16 Thomson Technology • No moisture or other contamination is present. • Electrical conductors are

Pagina 14

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 17 Thomson Technology 8. TRANSFER SWITCH MECHANISM – 100A-800A, S Style The transfer mechanism

Pagina 15

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 18 Thomson Technology Automatic operation may be regained by replacing the control circuit isolation

Pagina 16

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 19 Thomson Technology 9. TRANSFER SWITCH MECHANISM –1000A-1200A, T-Style The transfer mechanism

Pagina 17 - 6. OVER CURRENT PROTECTION

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 20 Thomson Technology connected. The drive system is self-engaging and will operate the tr

Pagina 18

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 21 Thomson Technology 10. RECOMMENDED MAINTENANCE DANGER!!!! Arc Flash and Shock Hazard. Will caus

Pagina 19 - MECHANISM

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 22 Thomson Technology 10.10. The motor and gearbox on all Transfer Mechanism styles are permanently

Pagina 20

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 23 Thomson Technology 11. FRONT VIEW (TYPICAL) 3 / 4 POLE 100A-250A S-Style TRANSFER MECHANISM

Pagina 21 - 8.1. MANUAL OPERATION

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 24 Thomson Technology 12. FRONT VIEW (TYPICAL) 3 POLE 400A-800A S-Style TRANSFER MECHANISM (Mechani

Pagina 22

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 25 Thomson Technology 13. FRONT VIEW (TYPICAL) 3 / 4 POLE 1000A-1200A T-Style TRANSFER MECHANISM

Pagina 23 - 9.1. MANUAL OPERATION

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 Thomson Technology TABLE OF CONTENTS 1. PRODUCT REVISION HISTORY 1 2. EQUIPMENT STORAGE 1 2.1

Pagina 24

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 26 Thomson Technology 14. CONNECTION CONFIGURATION OPTIONS

Pagina 25

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 27 Thomson Technology 15. CABLE TERMINAL INFORMATION TERMINAL RATING CONNECTION TIGHTNESS (In-lbs)

Pagina 26

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 28 Thomson Technology 16.2. INTERRUPTING CAPACITY CURRENT RATINGS (ALL MODELS WITH INTEGRAL OVERCU

Pagina 27

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 29 Thomson Technology The interconnected system shall be evaluated to ensure compliance wit

Pagina 28

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 30 Thomson Technology 18. TROUBLESHOOTING DANGER!!!! Arc Flash and Shock Hazard. Will cause severe

Pagina 29

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 31 Thomson Technology - Defective TSC 80 controller (verify output signals with circuit board mount

Pagina 30

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 32 Thomson Technology NOTE There are no user serviceable components located on the TSC 80

Pagina 31

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 33 Thomson Technology Component Description Thomson Technology Part Number Comments (100A-250A S Sty

Pagina 32 - 17.1. PERFORMANCE TEST

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 34 Thomson Technology 21. NOTES

Pagina 33

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 35 Thomson Technology 22. PERFORMANCE TEST FORM This form should be retained by those in charge of

Pagina 34 - 18. TROUBLESHOOTING

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 Thomson Technology 9. TRANSFER SWITCH MECHANISM –1000A-1200A, T-STYLE 19 9.1. MANUAL OPERATION

Pagina 36 - 19. REPLACEMENT PARTS

APPENDIX “A” THOMSON TECHNOLOGY© TYPICAL AUTOMATIC TRANSFER SWITCH COMMISSIONING PROCEDURES Model Series TS 870 Note: The following commiss

Pagina 37 - 20. PRODUCT RETURN POLICY

APPENDIX “A” THOMSON TECHNOLOGY© TYPICAL AUTOMATIC TRANSFER SWITCH COMMISSIONING PROCEDURES Model Series TS 870 3) For 240V High Leg Delt

Pagina 38 - 21. NOTES

APPENDIX “A” THOMSON TECHNOLOGY© TYPICAL AUTOMATIC TRANSFER SWITCH COMMISSIONING PROCEDURES Model Series TS 870 iii) Green “Load” LED is “ON”

Pagina 39 - 22. PERFORMANCE TEST FORM

APPENDIX “A” THOMSON TECHNOLOGY© TYPICAL AUTOMATIC TRANSFER SWITCH COMMISSIONING PROCEDURES Model Series TS 870 Hold the push button “ON” for

Pagina 40

APPENDIX “B” THOMSON TECHNOLOGY© INSTRUCTIONS TO CHANGE SYSTEM VOLTAGE ON TS 870 SERIES TRANSFER SWITCHES WITH TSC 80 CONTROLLER 9087A - 198th S

Pagina 41 - APPENDIX “A”

APPENDIX “B” THOMSON TECHNOLOGY© INSTRUCTIONS TO CHANGE SYSTEM VOLTAGE ON TS 870 SERIES TRANSFER SWITCHES WITH TSC 80 CONTROLLER 9087A - 198th S

Pagina 42

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 1 Thomson Technology 1. PRODUCT REVISION HISTORY The following information provides an historical s

Pagina 43

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 2 Thomson Technology ventilated area free of corrosive agents including fumes, salt and co

Pagina 44

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 3 Thomson Technology 3.2. TRANSFER SWITCHES WITH INTEGRAL OVER CURRENT PROTECTION For models of tr

Pagina 45 - APPENDIX “B”

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 4 Thomson Technology To change the transfer switch voltage, refer to “INSTRUCTIONS TO CHANGE SYSTEM

Pagina 46

TS 870 TRANSFER SWITCH PM062 REV 5 08/05/05 5 Thomson Technology the supply source be arranged such that the phase of highest potential with res